Monitoring Devices
Manufacturer of a wide range of products which include phase monitoring device, pvmd phase monitoring device, pvmd-g phase voltage monitoring device and pvimd phase voltage current monitoring device.
Phase Monitoring Device
Product Price: Rs 1,110 / PieceGet Best Price
Minimum Order Quantity: 10 Piece
Product Details:
Brand | EAPL |
Input Voltage | 440V AC,3 Phase |
Operating Voltage Range | -30% to +20% of 440 V |
Input Frequency | 50Hz+/-5% |
Power Consumption | 35VA / 7W |
Dimensions | 45x75x116 mm |
- Auto / Manual mode (only for PMD-01 and SPP-T)
- Front button and external potential free (zero volt / no voltage)terminal contacts for resetting in manual mode.
- LED indication for power, relay status and fault condition.
- Trip delay time and limits of all parameters are factory set
- Monitors phase sequence, failure, unbalance and under voltage in a 3 phase 3 wire system and trips under such conditions
- Over-all45 x 75 x 116mm (W x H x D)
Additional Information:
- Item Code: PMD-01
- Pay Mode Terms: T/T (Bank Transfer)
- Port of Dispatch: Bangalore
- Production Capacity: 1000
- Delivery Time: 3 to 4 weeks from the date of confirmed PO
Get Best QuoteRequest A Callback
PVMD Phase Monitoring Device
Product Price: Rs 2,560 / PieceGet Best Price
Minimum Order Quantity: 10 Piece
Product Details:
Brand | EAPL |
Input Voltage | 415V AC |
Input Frequency | 50Hz+/-10% |
Power Consumption | 5VA / 1W |
Operation Temperature | -10 to +55 Deg C |
Storage Temperature | -25 to +80 Deg C |
Dimension | 96 X 96 X 97.5 mm |
Phase | 3Ph,4Wire |
- Din sized enclosure
- Auto / Manual switch
- Front button for resetting in manual mode
- External potential free (zero volt /no voltage) terminal contacts for auto mode.
- LED indication for relay status
- Window displays the type of fault that has occurred during unhealthy condition
- Trip delay time and limits for each parameter can be set digitally
- All programs can be locked by removing short link across specified terminals
- Unwanted parameters can be by-passed as per user''s choice.
- Relay can be configured to have NO or NC status during healthy condition
- Unit will retain fault till accepted in manual mode
- Monitors and trips the circuit after the set trip delay time when ever power unhealthiness (phase failure, phase sequence, phase unbalance under voltage or over voltage) occurs.
- Displays all the 3 phase voltages in a scrolling fashion during healthy condition.
- PVMD Panel / Flush mounting
Other Technical Details:
- Function : Phase Unbalance,Phase Reversal,Phase Failure, Under Voltage, Under and Over Current Monitor and Control
- Control output : : 1c/o rated for 10A @ 250VAC /28VDC resistive load
Accuracy :
- Voltage : 4V of display value
Genera Trip setting:
- Phase Unbalance : 1-20 %( Adj.)
- Under Voltage : 5 to 100V AC
- Over Voltage : 5 to 100V AC
- Minimum sensing current : 0.5A
- Maximum setting current : 5A(Above 5A ->Ext.CT can be used,CT setting max.2500/5 in steps of 5)
- Trip time delay : 1 to 250secs settable for UB, OV, UV
- Trip time accuracy : 1% of set delay 2sec.
- Phase Failure trip time delay : < 5 sec
- Phase Reverse trip time delay : Instantaneous
- Recovery Time : 2 sec Min.
- Power On Delay : 10 sec Max.
- Inrush current delay : 1 to 60secs settable
- Mode of Operation : Auto/Manual
- Humidity : MAX 85% RH @ 40 0°C
Mechanical Endurance :
- Service life (under no load) : 106 operations minimum
- Rated frequency of operation : : 1800 5% operations per hour max.
Electrical Endurance:
- Electrical life (under full load) : 105 operations minimum
Electrical Safety:
- Insulation resistance : >100M ohm @ 500V DC
- Dielectric strength : 2.5KV AC, 50Hz for 1 minute. (Between current carrying& non-current carrying parts) 1.5KV AC, 50Hz for 1 minute. (Between contacts & control circuit) 750V AC, 50Hz for 1 minute. (Between non-continous relay contacts)
- Electrical connection : : Screw type terminals with self lifting clamps
Applications: Any 3 phase 4wire systems like motors, pumps, generators / distribution / MCC panels, air conditioners, elevators, cranes, escalators.
Additional Information:
- Item Code: PVMD
- Pay Mode Terms: T/T (Bank Transfer)
- Port of Dispatch: Bangalore
- Production Capacity: 1000
- Delivery Time: 3 to 4 weeks from the date of confirmed PO
Get Best QuoteRequest A Callback
PVMD-G Phase Voltage Monitoring Device
Product Price: Rs 2,590 / PieceGet Best Price
Product Details:
Input Voltage | 415V AC, 3 Phase |
Frequency (Hz) | 50 Hz, +/-10% |
Brand | EAPL |
Power | 5VA / 1W |
Recovery Time | Minimum 2 Sec |
Operation Temperature | -10 to +55 Deg C |
Storage Temperature | -25 to +80 Deg C |
Dimensions | 76x78x115 mm |
- Din sized enclosure
- Auto / Manual switch
- Front button for resetting in manual mode
- External potential free (zero volt /no voltage) terminal contacts for auto mode.
- LED indication for relay status
- Window displays the type of fault that has occurred during unhealthy condition
- Trip delay time and limits for each parameter can be set digitally
- All programs can be locked by removing short link across specified terminals
- Unwanted parameters can be by-passed as per user's choice.
- Relay can be configured to have NO or NC status during healthy condition
- Unit will retain fault till accepted in manual mode
- Monitors and trips the circuit after the set trip delay time when ever power unhealthiness (phase failure, phase sequence, phase unbalance under
- voltage or over voltage) occurs.
- Displays all the 3 phase voltages in a scrolling fashion during healthy condition.
- PVMD-G Din Rail mounting
Other Technical Details:
- Function : Phase Unbalance, Phase Reversal, Phase Failure, Under Voltage and Over Voltag e Monitor and Control
- Contro output : 1c/o rated for 10A @ 250VAC /28VDC resistive load
Accuracy :
- Voltage : ±4V of Display Value
- Trup Time : ± 1% of set delay ±2sec.
General :
- Trip Settings: Phase Unbalance → 1-20 %( Adj.) Under Voltage → 5 to 100V AC Over Voltage → 5 to 100V AC
- Trip time delay : 1 to 250secs settable for UB, OV, UV,OC,UC
- Phase Failure trip time delay : <5 Sec
- Phase Reverse trip time delay : : Instantaneous
- Mode of Operation : Auto/Manual
- Humidity : MAX 85% RH @ 40°C
Mechanical Endurance:
- Service life (under no load) : 106 operations minimum
- Rated frequency of operation : 1800 ± 5% operations per hour max.
Electrical Endurance: :
- Electrical life (under full load) : 105 operations minimum
Electrical Safety:
- Insulation resistance : >100M ohm @ 500V DC
- Dielectric strength : 2.5KV AC, 50Hz for 1 minute. (Between current carrying& non-current carrying parts) 1.5KV AC, 50Hz for 1 minute. (Between contacts & control circuit) 750V AC, 50Hz for 1 minute. (Between non-continous relay contacts)
- Electrical connection : Screw type terminals with self lifting clamps
Applications: Any 3 phase 4wire systems like motors, pumps, generators / distribution / MCC panels, air conditioners, elevators, cranes, escalators.
Additional Information:
- Item Code: PVMD-G
Get Best QuoteRequest A Callback
PVIMD Phase Voltage Current Monitoring Device
Product Price: Rs 4,630 / PieceGet Best Price
Product Details:
Brand | EAPL |
Input Voltage | 415V AC |
Input Frequency | 50Hz+/-10% |
Power Consumption | 5VA / 1W |
Dimension | 96 X 96 X 97.5 mm |
Phase | 3Ph, 4Wire |
- Din sized enclosure l
- Auto / Manual switch
- Front button for resetting in manual mode
- External potential free (zero volt /no voltage) terminal contacts for auto mode.
- LED indication for relay status
- Window displays the type of fault that has occurred during unhealthy condition
- Trip delay time and limits for each parameter can be set digitally
- All programs can be locked by removing short link across specified terminals
- Unwanted parameters can be by-passed as per user's choice.
- Relay can be configured to have NO or NC status during healthy condition
- Unit will retain fault till accepted in manual mode
- Monitors and trips the circuit after the set trip delay time when ever power unhealthiness (phase failure, phase sequence, phase unbalance under
- voltage, over voltage, under current or over current occurs)
- Displays all the 3 phase voltages and 3 phase currents in a scrolling fashion during healthy condition.
- User can program nominal current. Under current and over current limits can be set in percentage with reference to nominal current.
- User can set the in-rush time delay.
- Terminals to connect all the 3 phase CTs are provided.
- CT primary can be programmed up to 2500 in steps of 5. CT secondary will be factory set for 5.
- PVIMD – Panel / Flush mounting.
Other Technical Details:
- Function : Phase Unbalance,Phase Reversal,Phase Failure, Under &Over Voltage, Under and Over Current Monitor and Control
Accuracy :
- Voltage : ± 4V of display value
- Current : ± 5% of Ib ± 1 digit. (Ib=5A)
- Trip time : ± 1% of set delay ±2sec.
Genera Trip setting:
- Phase Unbalance : 1-20 %( Adj.)
- Under Voltage : 5 to 100V AC
- Over Voltage : 5 to 100V AC
- Over Current : 105% to 800%
- Under Current : 20%* to 95%
- Minimum sensing current : 0.5A
- Maximum setting current : 5A(Above 5A ->Ext.CT can be used,CT setting max.2500/5 in steps of 5)
- Trip time delay : 1 to 250secs settable for UB, OV, UV,OC,UC
- Phase Failure trip time delay : Less than 5 sec
- Phase Reverse trip time delay : Instantaneous
- Recovery Time : 2 sec Min.
- Power On Delay : 10 sec Max.
- Inrush current delay : 1 to 60secs settable
- Mode of Operation : Auto/Manual
- Humidity : MAX 85% RH @ 40 0 C
- Service life (under no load) : 106 operations minimum
- Rated frequency of operation : : 1800 ± 5% operations per hour max.
Electrical Endurance:
- Electrical life (under full load) : 105 operations minimum
Electrical Safety:
- Insulation resistance : >100M ohm @ 500V DC
- Dielectric strength : 2.5KV AC, 50Hz for 1 minute. (Between current carrying& non-current carrying parts) 1.5KV AC, 50Hz for 1 minute. (Between contacts & control circuit) 750V AC, 50Hz for 1 minute. (Between non-continous relay contacts)
- Electrical connection : : Screw type terminals with self lifting clamps
Additional Information:
- Item Code: PVIMD
Get Best QuoteRequest A Callback